KCO-Fiver-MTP-MPO-QSFP-Banner-shafi-1

Na'urar Fiber ta Waje Mai Sauƙi Na Yanayi Guda ɗaya

Takaitaccen Bayani:

+ Yi amfani da shi don na'urar lantarki ta waje.

+ Babban bututun da ke kwance a waje, kebul na fiber optic,

+ Adadin zare: zare 2, zare 4, zare 6, zare 8, zare 12, zare 24.

+ Nau'in zare: SM G652D, SM G657A1, SM G657A2, MM OM1, MM OM2, MM OM3, MM OM4, MM OM5

+ Bakin waje na kebul: PE, baƙi

+ Diamita na kebul: 6.5mm, 7.0mm, 7.0mm

+ Buga kebul da lakabi: karɓa.


  • Farashin FOB:Dalar Amurka $0.5 - 9,999 / Kashi
  • Ƙaramin Oda:Guda/Guda 100
  • Ikon Samarwa:Guda/Guda 10000 a kowane wata
  • Cikakken Bayani game da Samfurin

    Alamun Samfura

    Halayen Injin Fiber Optic na GYXTW:

    Kebul na GYXTW Diamita na kebul Nauyi
    Adadin zare: zare 2 zuwa zare 24 8.0mm+-0.5mm 70kg/km
    7.0mm+-0.3mm 50kg/km
    Matsakaicin zafin jiki -40°C+70°C
    Ma'aunin Lanƙwasawa Mafi Karanci (mm) Na dogon lokaci 10D
    Ƙaramin LanƙwasawaRadius(mm) Na ɗan gajeren lokaci 20D
    Ƙarfin Tashin Hankali Mai Ƙaranci (N) Na dogon lokaci 1200
    Ƙarfin Tashin Hankali Mai Ƙaranci (N) Na ɗan gajeren lokaci 1500
    Zafin aiki -40°C+70°C
    Zafin shigarwa -20°C+60°C
    Zafin ajiya -40°C+70°C

    Siffar zare:

    Salon zare Naúrar SM

    G652D

    SM

    G657A

    MM

    50/125

    MM

    62.5/125

    MM

    OM3-300

    MM

    OM4-550

    Yanayi nm 1310/1550 1310/625 850/1300 850/1300 850/1300 850/1300
    Ragewar dB/km ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0 ≤3.5/2.2
    Watsawa 1550nm Ps/(nm*km) ≤18 ≤18 ----- -----

    -----

    -----

      1625nm Ps/(nm*km) ≤22 ≤22 ----- -----

    -----

    -----

    Bandwidth 850nm MHZ.KM -----   ≥400 ≥160    
      1300nm MHZ.KM -----   ≥800 ≥500
    Sifili tsawon watsawa nm ≥1302

    ≤1322

    ≥1302

    ≤1322

    ----- ----- ≥ 1295,

    ≤1320

    ≥ 1295,

    ≤1340

    Sifili gangaren watsawa nm ≤0.091 ≤0.090 ----- ----- ----- -----
    Mafi girman PMD Fiber na mutum ɗaya ≤0.2 ≤0.2 ----- ----- ≤0.11  
    Darajar Haɗin Tsarin PMD Ps(nm2*km) ≤0.08 ≤0.1 ----- ----- ----- -----
    Tsawon tsayin daka na fiber λc nm ≥1180

    ≤1330

    ≥1180

    ≤1330

    ----- ----- ----- -----
    Latsen kebul

    tsawon λcc

    nm ≤1260 ≤1260 ----- ----- ----- -----
    MFD 1310nm um 9.2±0.4 9.0±0.4 ----- ----- ----- -----
      1550nm um 10.4±0.8 10.1±0.5 ----- ----- ----- -----
    Lambobi

    Buɗewar Hanya (NA)

    ----- ----- 0.200± 0.015 0.275±

    0.015

    0.200±

    0.015

    0.200±

    0.015

    Mataki (matsakaicin hanya biyu

    aunawa)

    dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Rashin daidaito tsakanin tsawon zare da kuma ma'auni dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Bambancin baya-baya

    ma'aunin ƙididdiga

    dB/km ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08 ≤0.08
    Daidaito tsakanin raguwa dB/km ≤0.01 ≤0.01  
    Diamita na tsakiya um 9 9 50±1.0 62.5±2.5 50±1.0 50±1.0
    Diamita na rufin rufi um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
    Rufewa ba tare da zagaye ba % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
    Diamita na shafi um 242±7 242±7 242±7 242±7 242±7 242±7
    Shafi/chaffinch

    kuskuren da aka mayar da hankali a kai

    um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
    Shafi mara zagaye % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
    Kuskuren haɗin kai na Core/cladding um ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5 ≤1.5
    Lanƙwasa (radius) um ≤4 ≤4 ----- ----- ----- -----

    Launin zare:

    1 2 3 4 5 6
    Shuɗi Lemu Kore Ruwan kasa Launin toka Fari
    7 8 9 10 11 12
    Ja Baƙi Rawaya Shuɗi Ruwan hoda Ruwa
    Lambobin -lambobin -launi na Fiber-Optic-Kebul

    Menene kebul na GYXTW?

    Ana sanya kebul na fiber optic na GYXTW, zare mai girman 250μm, a cikin wani bututu mai sassauƙa da aka yi da filastik mai girman modulus.

    Ana cika bututun da wani abu mai hana ruwa shiga.

    An naɗe bututun da wani Layer na PSP a tsayi.

    Ana amfani da kayan da ke toshe ruwa tsakanin PSP da bututun da ba shi da ruwa don kiyaye kebul ɗin ya yi ƙanƙanta kuma ya hana ruwa shiga.

    An sanya wayoyi biyu na ƙarfe masu layi ɗaya a ɓangarorin biyu na tef ɗin ƙarfe.

    Ana kammala kebul ɗin da murfin polyethylene (PE), launin baƙi, don kare zaren daga UV.

    Gine-gine:

    Kebul na KCO GYXTW

    Halaye:

    Memba mai layi ɗaya na waya mai waya, mai cikewa yana kare bututun fiber ɗin ƙarfe mai sulke.

    Kyakkyawan aikin injiniya da muhalli.

    Tsarin ƙarami, ana iya shigar da nauyi mai sauƙi cikin sauƙi kuma a sarrafa shi cikin sauƙi.

    Akwai wasu zare da ake da su: Yanayin guda ɗaya (G652D, G657A, G657B) da Multimode (OM1, Om2, Om3, OM4, OM5)

    Adadin zare: 2fo ~ 12fo

    Zaɓin diamita: 6.0mm, 7.0mm (tsohon aiki), 8.0mm

    Aikace-aikace:

    + An yarda da rarrabawa a waje.

    + Ya dace da hanyar shimfida bututun iska, bututun mai.

    + Sadarwar hanyar sadarwa ta nesa da ta yankin.

    OM3 5025 GYXTW Na gani na waje5

    Shiryawa:

    Kamfanin Kebul na Fiber Optic na KCO

  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi