KCO-Fiver-MTP-MPO-QSFP-Banner-shafi-1

16F ULL MPO Yanayin guda ɗaya SM MPO adaftar gani / haɗin fiber na MTP

Takaitaccen Bayani:

+ Sunan Samfuri:

Adaftar gani ta MPO 16F

Mai haɗa fiber na MTP 16F

+ Nau'in Zare: Yanayi ɗaya (SM)

+ Adadin zare: 16F

+ Flange: Akwai

+ Asarar Shigarwa: 0.15dB Asarar Ƙaranci Mai Kyau (Rashin Elite)

+ Farashin Samfuri/N:

KCO-MPO16-ADT-B

KCO-MTP16-ADT-B

+ Launin Jiki: Baƙi

+ Tashar adaftar don shigarwa: tashar SC simplex

+ MOQ: 1pc

+ Matsayin Hannun Jari: akwai

+ Lokacin jigilar kaya: nan da nan


  • Farashin FOB:Dalar Amurka $0.5 - 9,999 / Kashi
  • Ƙaramin Oda:Guda/Guda 100
  • Ikon Samarwa:Guda/Guda 10000 a kowane wata
  • Cikakken Bayani game da Samfurin

    Alamun Samfura

    Bayanin Adaftar Fiber na 16F SM MPO / Ma'aunin Fiber na MTP

    + 16F MPO na ganiadaftar / MTP fiber coupler (wanda galibi ana amfani da shi tare da haɗin MPO-16 / MTP-16) adaftar fiber optic ce mai yawan yawa wacce ake amfani da ita don haɗa kebul na MPO / MTP guda biyu masu fiber 16 ko haɗa transceiver a cibiyoyin bayanai.

    + Yawanci suna da tsarin maɓallan da za a iya amfani da su wajen hana shigar da kebul na fiber 12 cikin saitunan fiber 16 ba bisa ƙa'ida ba.

    + Ana amfani da shi don haɗin MPO-16 / MTP-16.

    + Adaftar gani ta MPO / MTP fiber optic coupler suna da nau'ikan 2:

    - Nau'in da ke adawa da shi (Maɓalli Har zuwa Maɓalli Ƙasa): amfani da kebul na MPO/MTP na akwati na Type A.

    - Nau'in da aka daidaita (Maɓalli har zuwa Maɓalli sama): amfani da kebul na MPO / MTP na akwati na Type B.

    + Kamar yadda aka saba amfani da adaftar fiber optic, na'urar haɗa fiber optic na MPO-16 / adaftar fiber MTP-16 galibi tana amfani da ita akan allon facin fiber optic, akwatin module na fiber optic, akwatin tashar fiber optic wanda ke zuwa da kebul na MPO/MTP.

    + Adaftar gani ta MPO 16F / Maɗaurin fiber na MTP shine adaftar flange mai ramin sukurori a gefen adaftar biyu don ya fi kyau a haɗa adaftar a cikin farantin faci.

    Matsayin maɓalli na adaftar gani na MPO / MTP na haɗin fiber + 16F ya bambanta da adaftar 12F MPO / MTP:

    Adaftar MPO 12F vs 16F

    Madannin fiber na gani na MPO-16 / adaftar fiber na MTP-16 Girman:

    MPO 16F-05

    Bayani dalla-dalla na Fiber MTP Adaftar Tantancewar 16F MPO

    Nau'in Mai Haɗawa MPO/MTP
    Launin Jiki Baƙi
    Yanayin Fiber Yanayi ɗaya
    Adadin Zare 16F
    Asarar Shigarwa ≤0.15dB
    Dorewa tsakanin Ma'aurata Sau 500
    Flange Tare da flange
    Tashar adaftar SC Simplex
    Maɓallin Gabatarwa Maɓalli Har zuwa Maɓalli Sama

    Maɓalli Har zuwa Maɓalli Ƙasa

    Hotunan samfurin MTP Fiber Adaftar Na gani na 16F MPO:

    Matsayin MPO MTP 16F

    Aikace-aikacen Fiber Maɗaukaki na MTP na Fiber na 16F MPO

    + Maganin kebul na MPO MTP

    + Babban ma'aunin yawa

    + Panel ɗin faci mai yawa

    + Cibiyar bayanai

    + Tsarin canja wurin kebul na AI

    + Tsarin canja wurin hanyar sadarwa ta tauraro

    + Maganin FTTx

    + WAN / LAN

    + PON, EPON, GPON

     

    16F MPO Na'urar Fiber Mai Haɗawa ta MTP

    Yana tallafawa gudu har zuwa 40G, 100G, 200G, 400G

    Mai haɗa shafin turawa/jawo yana shigarwa/cirewa da hannu ɗaya.

     8fibers, 32fibers MTP/MPO masu haɗin.

    Akwai yanayi ɗaya da Multimode.

    Daidaito mai girma.

    Haɗi mai sauri da sauƙi.

    Gidaje masu sauƙi da ɗorewa na filastik.

    Tsarin haɗin guda ɗaya yana ƙara ƙarfin haɗin gwiwa yayin da yake rage samar da tarkace.

    Launin Ruwa, Violet don zaɓa.

    Babban abin sawa.

    Maimaitawa mai kyau.

    Adaftar SC mai kaifi, tare da flange, mai sauƙin shigarwa.


    Buƙatar Muhalli:

    Zafin aiki

    -20°C zuwa 70°C

    Zafin ajiya

    -40°C zuwa 85°C

    Danshi

    95%RH


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi